How Many Bags of Concrete for a 24-Inch Sonotube Pier?
Calculate the exact 80-lb and 60-lb bag counts, cubic feet, cubic yardage, and frost-depth requirements for a 24-Inch diameter cylindrical concrete pier or Sonotube form.
Net volume: 9.42 ft³ (0.349 yd³) per hole • Or 24 60-lb bags
Typical zone: Mid-Atlantic, Lower Midwest, Pacific Northwest, and High Elevation South.
Net volume: 12.57 ft³ (0.465 yd³) per hole • Or 31 60-lb bags
Typical zone: Upper Midwest, New England, Northeast, and Rocky Mountain regions.
How to measureConcrete Column Diagram
24-Inch Sonotube Concrete Bag Chart by Depth
Concrete volume and 80-lb bag requirements for a 24" round tube across standard hole depths and pier quantities (includes 10% safety margin):
| Hole Depth | Cu Ft / Pier | 1 Pier (80 lb) | 4 Piers (80 lb) | 6 Piers (80 lb) | 8 Piers (80 lb) | 1 Pier (60 lb) |
|---|---|---|---|---|---|---|
| 24" (2 ft) | 6.28 ft³ | 12 bags | 47 bags | 70 bags | 93 bags | 16 bags |
| 30" (2.5 ft) | 7.85 ft³ | 15 bags | 58 bags | 87 bags | 116 bags | 20 bags |
| 36" (3 ft) | 9.42 ft³ | 18 bags | 70 bags | 104 bags | 139 bags | 24 bags |
| 42" (3.5 ft) | 11 ft³ | 21 bags | 81 bags | 121 bags | 162 bags | 27 bags |
| 48" (4 ft) Standard 4ft | 12.57 ft³ | 24 bags | 93 bags | 139 bags | 185 bags | 31 bags |
| 60" (5 ft) | 15.71 ft³ | 29 bags | 116 bags | 173 bags | 231 bags | 39 bags |
* Bag quantities are rounded up to the nearest full sack. Calculations assume 0.60 cu ft per 80-lb bag and 0.45 cu ft per 60-lb bag with a 10% allowance for hole irregularity and bell bases.
Structural Code & Reinforcement for a 24-Inch Pier
Engineering recommendations per IRC Section R403 (Footings and Foundations) and ACI 318:
Frost Depth Code (IRC R403.1.4)
Footings must be placed a minimum of 12 inches below undisturbed soil and below the local frost depth line to protect the structure against soil expansion and frost heave.
Rebar Reinforcement
Six to eight #5 or #6 rebar with continuous spiral or welded wire cage. Maintain at least 1.5 inches of concrete cover between rebar and the inner tube wall to prevent moisture ingress and steel corrosion.
Estimated Axial Load Capacity
~50,000 – 80,000+ lbs. Actual load capacity depends on native soil bearing pressure (typically 1,500 to 2,500 PSF) and concrete compressive strength.
Concrete Mix Spec (3000 vs 4000 PSI)
Use 3,500 to 4,000 PSI commercial high-strength concrete for piers supporting elevated structures. Read our Concrete Mix Comparison Guide for cure time and strength charts.
Application Notes for 24-Inch Piers (Heavy Foundation Caissons & Bell Piers)
A 24-inch round pier functions as an engineered drilled caisson supporting residential room additions, heavy structural steel columns, and retaining wall end buttresses. Due to the high concrete volume (over 1/2 cubic yard per 3-ft hole), ready-mix concrete delivery is strongly advised.
Explore Other Sonotube & Pier Diameters
All Standard Sonotube Tube Diameters:
Frequently Asked Questions: 24-Inch Sonotube Pier
How many 80 lb bags of concrete do I need for a 24-inch Sonotube 4 feet deep?
For a single 24-inch diameter Sonotube poured 4 feet (48 inches) deep, you need 24 eighty-pound bags of concrete (or 31 sixty-pound bags), factoring in a 10% safety margin for hole bell-out. The exact volume is 12.57 cubic feet (0.465 cubic yards). For a standard 4-pier deck project, you will need 93 eighty-pound bags total.
How many bags of concrete for a 24-inch Sonotube 3 feet (36 inches) deep?
A 24-inch Sonotube 3 feet deep requires 18 eighty-pound bags of concrete (or 24 sixty-pound bags) per pier. The net volume per hole is 9.42 cubic feet. If pouring 4 piers, you will need 70 eighty-pound bags; for 6 piers, you will need 104 eighty-pound bags.
How deep should a 24-inch concrete pier be?
Under International Residential Code (IRC Section R403.1.4), exterior concrete footings and piers must extend below the local frost line to prevent frost heave from lifting and cracking the structure. In southern US states, minimum depth is typically 12" to 24", while northern states and Canada require 36", 42", 48", or even 60" deep piers. Consult our US Frost Depth Guide to find the exact code depth for your state.
Should I use 60 lb or 80 lb bags of concrete for Sonotubes?
Standard 80-lb bags yield approximately 0.60 cubic feet of mixed concrete, while 60-lb bags yield 0.45 cubic feet. For a 24-inch pier, 80-lb bags require mixing fewer total sacks (24 bags at 4 ft vs. 31 bags of 60-lb), reducing overall bag opening and mixing time. Use high-strength 4,000 PSI concrete (such as Quikrete 5000) for structural durability.